The following is specifications and dimensional information on the housing for the Moduloc Control Systems Model PF1000 Pathfinder Digital Hot Metal Detector (HMD) Scanner.

The PF1000 PATHFINDER Digital Hot Metal Detector (HMD) Scanner's electronic circuitry is packaged in a robust cast aluminum housing. The housing includes a large air cooled chamber which is separated from the electronic circuitry compartment. An air inlet is located in the rear of the cast aluminum housing. Pressurized air passes though this chamber, cooling the cast aluminum housing thus cooling the electronic circuitry. The air  vents in the front of the housing via a slot in front of the lens providing air purging. Further cooling of the air can be accomplished with the use of an in-line vortex tube air cooler.

Also available, an optional sealed water coolant radiator & separate air purging facility can be provided. The copper water coolant radiator is mounted internal to the air cooled chamber. Coolant inlet and outlet fittings are provided in the rear of the cast aluminum housing. An air inlet is fitted in the front nozzle of the housing and air is vented out the front of the nozzle in front of the lens.

 
Housing Specifications
 
Housing: Aluminum AL6, Oven baked blue paint
Housing Rating: IEC IP66, DIN, 89011
Weight: w/o Cable: 1.9 Kg
Connector: IP65 Plug/Socket
Cable Length: 1.5 M
 
Housing Dimensions

Air & Water Specifications
 

Air Pressure: 
1 - 2 cu ft./min at 5 PSI for normal conditions, non-instrument dry air and 10 - 15 PSI for severe conditions
Water Pressure:
1 - 2 bar

Water Volume: 
Regulate between 0.5 - 1 liter/min.
Water Temp.: 
For Ambient Temperature up to +80°C (176°F) use industrial quality water at 25°C (77°F)
For Ambient Temperature up to +120°C (250°F) use  water chilled to 5°C (41°F)
 
 

PF1000

Description Technical Info Housing
Info
Brochure Request
More Info
 
 

For Additional Info on the Moduloc Line of Hot Metal Detectors Click the Model Number Below:

 
Hot Metal Detectors MD9207 MD85100 MD95100 Series 9000 Remote Lenses
 

MODULOC Technology - The Total Sensor Solution

The MODULOC PF1000 Pathfinder Digital Hot Metal Detector (HMD) Scanner  is part of the MODULOC Steel Mill Sensor Group

 

 
For additional information please contact us at info@moduloc-sensors.com
 
MSE - MODULOC SENSORS ENTERPRISES LTD. copyright 2024 - www.moduloc-sensors.com

Disclaimer Moduloc Sensor Enterprises, Ltd  is not associated in anyway, means, shape or form with the former company Moduloc Control Systems Ltd of the United Kingdom